Campbell-hausfeld COM220 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Campbell-hausfeld COM220. Campbell Hausfeld COM220 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - COM220 Telephone Modem

COM220 Telephone ModemRevision: 3/07Copyright © 1997-2007Campbell Scientific, Inc.

Strona 2 - Warranty and Assistance

COM220 Telephone Modem CAMPBELLSCIENTIFICINC.CR10MADE IN USAWIRING PANEL NO.EARTHDIFFSEAG H L AG H L AG H L AG GGE3 AG4 5 678 910 1112GGGG12V 12VSWITC

Strona 3 - Table of Contents

COM220 Telephone Modem You can modify the following COM220 settings with DIP switches: 1) Communication mode (e.g., SDC or Modem Enable) 2) ME baud ra

Strona 4 - List of Tables

COM220 Telephone Modem 3) If using a non-PakBus datalogger (e.g., CR510, CR10X, CR23X, CR7, CR5000), verify that DIP switch 1 on the COM220 is in the

Strona 5

COM220 Telephone Modem in Setup’s PakBusPort [LoggerNet, Setup, PakBusPort (in the device map)] may limit the baud rate selected by the modems since i

Strona 6 - 1.2 Computer Requirements

COM220 Telephone Modem This is a blank page. 10

Strona 7 - 3. Installation

Appendix A. Changing COM220 Settings Changing any of the modem's settings may result in communication problems. After changing the settings, t

Strona 8 - 3.4 Telephone Service

Appendix A. Changing COM220 Settings TABLE A-1. Selecting ME Baud-rates via DIP Switches 3 and 4 ME Baud-rate Switch 3 Switch 4 9600 Open Open 38

Strona 9

Appendix A. Changing COM220 Settings FIGURE A-1. COM220 to Computer Connection To configure the COM220 with Hayes AT commands, follow these steps:

Strona 10 - 4. Modem Settings

Appendix A. Changing COM220 Settings 7) Follow the instructions that appear in the terminal emulator screen (Figure A-3). 8) Be sure to save all n

Strona 11 - 5. Troubleshooting

Appendix A. Changing COM220 Settings FIGURE A-3. Terminal Emulator Screen in Device Configuration HAYES AT COMMAND SUMMARY: This manual does not at

Strona 12

Warranty and Assistance The COM220 TELEPHONE MODEM is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship unde

Strona 13

Appendix A. Changing COM220 Settings M0 Speaker always off M1 (default) Speaker on during call establishment M2 Speak on during entire call sessio

Strona 14 - This is a blank page

Appendix A. Changing COM220 Settings FIGURE A-4. Send OS Screen in Device Configuration A.4 Program Examples A.4.1 ModemCallback Example (for CR1

Strona 15 - Settings

Appendix A. Changing COM220 Settings ModemCallBack(Result,ComSDC7,9600,0,"5551212","",40,60,Abort) CallTable Test5 NextScan

Strona 16 - A.2 Hayes AT Commands

Appendix A. Changing COM220 Settings The COM220 can return several possible responses once connected (each terminating in a carriage return): CAUTION

Strona 17

Appendix A. Changing COM220 Settings Do not put Instruction 97 inside a loop or conditional statement; it must be executed each time the table is run

Strona 18

Appendix A. Changing COM220 Settings 12: Initiate Telecommunications (P97) 1: 22 Phone Modem/9600 Baud ;set baud-rate/modem 2: 5 Disabled

Strona 19

Appendix A. Changing COM220 Settings SequentialMode DataTable (TestA,1,-1) DataInterval (0,2,Sec,10) Minimum (1,BatteryVoltage,FP2,0,False) Sample

Strona 20

Appendix B. CS I/O Connection B.1 CS I/O 9-Pin Connection The pin out of the connector is shown in Figure B-1. The direction of the signal relative

Strona 22

Appendix C. Theory of Operation C.1 Theory of Operation The COM220 modem is used to transmit data over bandwidth-limited channels such as telephone

Strona 23

COM220 Telephone Modem Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat®

Strona 24

This is a blank page.

Strona 25 - Datalogger Router

Appendix D. FCC Warning to Users of Class B Computing Devices This equipment generates, uses, and can radiate radio frequency energy, and if not ins

Strona 26

This is a blank page.

Strona 27 - B.1 CS I/O 9-Pin Connection

Appendix E. IC Information Industry Canada (IC) was formerly known as DOC. NOTE CP-01, Issue 8, Part I Section 14.1 “NOTICE: The Industry Canada la

Strona 28

This is a blank page.

Strona 30

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Strona 31 - Class B Computing Devices

COM220 Telephone Modem Table of Contents D. FCC Warning to Users of Class A Computing Devices...D-1 E. IC Information ...

Strona 32

COM220 Telephone Modem 1. Introduction 1.1 General Description The COM220 modem is a selectable-baud-rate modem employing the Hayes AT command set.

Strona 33 - Appendix E. IC Information

COM220 Telephone Modem The COM220 is connected to a CSI datalogger by a 9-pin subminiature D cable. This is the same 9-pin CS I/O interface common to

Strona 34

COM220 Telephone Modem 2. Specifications • Standards: V.92, K56Flex, V.90, V.34, V.32bis, V32, V23, V22bis, V22, V.21, B212, B103 • Registration:

Strona 35

COM220 Telephone Modem TABLE 1. Dataloggers that Require Direct 12 VDC Connection to COM220 CR10(X) with silver wiring panel CR10(X) with black CR10

Strona 36

COM220 Telephone Modem SE12 34 56 78H1234LDIFFHEX1HLHLLP2P112VGDC ONLYCAUTIONLUGGROUNDPOWER INWIRING PANELCR1000PERIPHERAL PORTRS-232 (Not Isolated)SN

Komentarze do niniejszej Instrukcji

Brak uwag